corrosion transmitter model ERT-03
ERT-03 transmitter is intrinsically safe (Ex ia IIC T4 Ga) with ability to obtain metal loss/corrosion rate from all ER probes produced in P.Z.D. ERT-3 measures the resistance of the probe element which changes over time then transfer to control room. A two-wire connection (loop powered 4-20 mA) is required for both instrument power and data transmission. This transmitter is well suited for plant locations, widely separated monitoring points. The instrument is housed in an Ex-d IIC T6 enclosure, and all external connections are weather-proof (IP65).

- Specifications
- Datasheet
| Type of Measurement | ER probe |
| Accuracy | ± 1 % |
| Output | 4-20 mA signal |
| Power requirement | 12 to 24 Vdc |
| Instrument weight | 1.5 Kg |
| Environment Safe | IP65 |
| Enclosure Spec. | Aluminum Ex d IIC T6 1.2 Kg 146(L) x 146(W) x 100(H) mm |
| Operating Temp. | -20 to 75 C |
| Max. probe cable length | 15 m |
| interval time | 1 to 24 hours |
| Probe cable | 6 wire cable (unarmored)- 3m max. |